FlowSphera 1.7.1 release notes
Pre-aggregated tables: a record that reached the collector more than ten minutes late, just before the moment an upgrade (+1 more change)
- Pre-aggregated tables: a record that reached the collector more than ten minutes late, just before the moment an upgrade to 1.3.3 or later switched the tables on, was summed up nowhere (seen as two records missing on long periods). Two hours after that moment the last two hours before it are now summed up again when they differ from the records; installs upgraded earlier get it once at the next start.
- Connect a device: the configuration for the device follows the Sampling field. sFlow uses the entered rate (until one is entered, the vendor's usual 1:1000 / 1:1024); NetFlow / IPFIX gets a sampler where it is set in the same configuration (Cisco Flexible NetFlow, Juniper, Arista, VyOS, pmacct); for the others the configuration says to set the same rate on the device. It changes as you type.